Almost every lighting question in Rwanda now has an LED answer, which is less helpful than it sounds: the word covers a 12W downlight and a 110W road luminaire, and getting the choice wrong is expensive in a way that is hard to see until the installation is finished. This page is for working out what you actually need. We supply, locally assemble, install and support LED lighting across Rwanda, and everything below links to the detail for whichever kind turns out to be yours.
The single most useful habit when buying lighting is to describe the problem rather than the product. "I need 40 LED panels" is a specification someone else made, possibly wrongly. "I have a 300 square metre open-plan office with a 2.8 metre ceiling" is a problem that has one right answer, and it is calculable.
Light is measured in lumens at the fitting and lux on the surface, and the second is the one that matters. Lux falls off with the square of distance, so a fitting's wattage tells you almost nothing without the mounting height. That is why the same 150W can be right for a warehouse at eight metres and badly wrong for the same floor area at three. A photometric study does that arithmetic, and the free lighting calculator will do it for a single room right now.
Six categories cover nearly every enquiry we get. Each links to a page with the specifications, the standards and the trade-offs.
Wattage is the number everyone compares and the least useful of the four. These are the ones to read instead, and all of them are published on every product in our catalogue.
| What to look at | Why it decides the outcome | Typical range in our catalogue |
|---|---|---|
| Lumens, and lumens per watt | Lumens are the light; watts are the bill. Efficacy is the ratio, and it is the real comparison between two fittings | Published per product |
| Colour temperature (CCT) | 4000K for workplaces, 6500K for industrial and inspection, 3000K and below for hospitality and homes | 2700K – 6500K |
| IP rating | IP20 indoors and dry, IP44 splashes, IP65 dust and jets, IP66 heavy weather and road use | IP20, IP44, IP65, IP66 |
| Warranty, and who honours it | A 5-year warranty from a supplier with no local stock is a 5-year wait | 2, 3 and 5 years, parts held in Kigali |
Wattage can be corrected by adding or removing fittings. Colour temperature cannot be corrected at all without replacing them, and it is the thing people most often get wrong, usually by buying 6500K because it looks brighter in a shop.
It does look brighter, and it is not. A 4000K and a 6500K fitting of the same output put the same amount of light on the desk; the cooler one just reads as harsher. For offices, classrooms, clinics and retail, 4000K is the right default. Keep 6500K for industrial floors and inspection work where its coldness genuinely helps. Use 3000K or 2700K for hospitality, reception and residential, where warmth is the point. The one rule with no exceptions: do not mix colour temperatures within a single visible space — it reads as a fault even to people who cannot name what is wrong.
Most LED enquiries are replacements rather than new installations: fluorescent battens in an office, metal halide or sodium in a warehouse or a yard, sodium on a road. Lighting is usually the easiest energy case in a building, because it runs predictable hours and the saving is measurable rather than modelled.
An energy retrofit begins with an audit of what is installed, what it consumes and what it costs to run, then a like-for-like LED and controls specification with the saving and the payback set out. Typical projects cut lighting energy by 50 to 70 per cent and pay for themselves in one to three years. A warning worth having early: swapping fitting-for-fitting usually over-lights the space, because the original design allowed for fluorescent depreciation. A study generally finds you need fewer fittings than you had, which makes the project cheaper, not more expensive.
We supply and locally assemble rather than importing sealed cartons. In practice that means three things that only show up later: every fitting is powered and checked before it leaves, drivers and optics are matched to what the study specified rather than to what was in the container, and a failed component in year three is a part on a shelf in Kigali rather than a whole fitting to re-import.
Warranties run to 5 years on street, solar street, high bay and tri-proof fittings, 3 years on panels, downlights, battens, drivers and control nodes, and 2 years on decorative fittings. [PLACEHOLDER: product certifications held — CE, RoHS, ISO or others — confirm which can be stated.]
We quote rather than publish prices, because a fitting price on its own is misleading: the number that matters is the installed cost of hitting a lux target, and that depends on how many fittings the space needs. Send the space and you will get a photometric study and a priced fixture schedule. Every product in the catalogue carries its full specification so the comparison can be made properly.
Over its life, almost always — and the case is usually made on energy and maintenance together rather than on energy alone, because LED fittings are replaced far less often. Typical retrofits here cut lighting energy by 50 to 70 per cent with a one to three year payback.
The first digit is protection against solids, the second against water. IP65 means dust-tight and protected against water jets, which is what outdoor and wash-down fittings need. Indoors and dry, IP20 is correct — paying for IP65 in an office is paying for a seal nobody will ever test.
Yes. Supply-only is available, and you can build a draft bill of quantities in the catalogue and send it for a formal quote. We will still tell you if the specification looks wrong for the space, and show you the calculation — but the decision stays yours.
[PLACEHOLDER: retail lamps and replacement bulbs — are these stocked, or is the range fittings only?] Our published range is complete luminaires, drivers and control gear rather than loose lamps.
Lumens measure the light a fitting emits. Lux measures the light landing on a surface — one lumen per square metre. Lux is what a standard specifies and what a person experiences, and it falls off with the square of distance, which is why mounting height changes everything and wattage alone tells you very little.
Dimensions, mounting height and what happens there. You will get a photometric study against the relevant standard and a priced fixture schedule — free on SIM-BI projects. Or browse the full catalogue with specifications and datasheets on every product.