Flood lights in Rwanda

A floodlight is the easiest lighting product to buy and the easiest to get wrong, because the thing that makes one good is invisible on a datasheet. Two 200W floodlights with identical lumen figures can produce completely different results on the same yard: one lighting the area evenly, the other putting a bright patch in the middle, glare in everyone's eyes and half its output over the boundary wall. What separates them is the optic, and the only way to compare optics is to model them.

Spill, glare and uniformity decide the outcome

Area lighting is judged on three things, and lumens is not one of them. Uniformity — the ratio between the darkest and brightest points — determines whether the eye can adapt and see detail anywhere in the area. Glare control determines whether people can look across the space without squinting, which on a yard where vehicles reverse is a safety matter. Spill control determines how much of what you paid for lands outside your boundary, annoying neighbours and lighting nothing useful.

All three are properties of the reflector and lens, not of the LED. This is why a photometric study matters more for floodlighting than for almost any other category: it models the actual optic across your actual area and reports the uniformity ratio, so two quotes can be compared on the result rather than on the wattage.

Car parks, yards and loading areas

The usual requirement is a modest light level held evenly across a large area, which is the opposite of what a cheap floodlight does. Mounting height is the main lever: higher mounting covers more area per fitting and gives better uniformity with less glare, at the cost of more structure. Four well-placed fittings on tall columns normally beat ten cheap ones on the building line.

Where the area is really a road rather than an area — an estate access route, a service road — it should be designed as road lighting instead, because the standards and the optics are different. Street lighting in Rwanda covers that. Indoor car parks and basements are a different fitting again: sealed tri-proof battens, covered on the indoor lighting page.

Security lighting: more light is not more security

The instinct with security lighting is to add brightness, and past a fairly low level that makes things worse. A very bright light creates deep shadow immediately beside it and destroys the dark adaptation of anyone looking into it, including a guard and a camera. Glare also tends to blind the observer rather than reveal the intruder.

What works is even, moderate light with good uniformity, aimed so that the observer has the light behind them and the approach is lit from the observer's side. Where there are cameras, the camera's requirements govern: most need less light than people assume but are far more sensitive to uneven light and to pointing anywhere near a light source.

Motion-triggered floodlighting is genuinely useful on perimeters, both for the deterrent effect of a change and because it keeps consumption down. On sites with no grid, solar floodlighting with motion sensing is the obvious arrangement — see the note below on availability.

Sports and pitch lighting

Sports lighting is the most standards-driven of all floodlighting, and the standard is EN 12193. It sets illuminance and uniformity per class of play, and the classes differ by an order of magnitude: recreational and training use at the bottom, club competition in the middle, and televised play at the top, where the requirements include vertical illuminance toward the cameras and limits on flicker that an ordinary driver cannot meet.

The practical consequence is that the first question is not how many floodlights, it is what level of play. A pitch designed for training and later used for a televised match will fail; a pitch designed for broadcast when it will only ever host training costs several times what it needed to. Mast positions and heights follow from the class, and on a football pitch they are constrained by the rules about where masts may stand.

[PLACEHOLDER: sports lighting — confirm whether SIM-BI quotes pitch and stadium schemes, to which EN 12193 classes, and whether mast supply and structural design are included or by others.]

High mast lighting

High mast lighting — a small number of very tall columns carrying clusters of floodlights — suits large open areas such as interchanges, freight yards, container terminals and parking fields. It gives excellent uniformity over a wide area from few positions, and reduces the number of obstructions at ground level.

The trade-offs are maintenance access and structural design, both of which have to be decided before the lighting is specified rather than after: whether the mast is a climbing mast or has a lowering device changes the fitting choice, and the structure has to be engineered for wind loading with the full headframe fitted.

[PLACEHOLDER: high mast lighting — confirm whether SIM-BI supplies or installs high mast schemes, available mast heights, and whether lowering devices are offered.]

What we can quote today

Being straight about this is more useful to you than a page that implies a catalogue we do not have. Our published range covers street and solar street lighting, indoor and industrial LED, decorative and emergency lighting, LED drivers and smart control nodes — all with full specifications in the catalogue.

Floodlighting is not yet published as a range. We will design a floodlighting scheme — the photometric study, the uniformity and spill analysis, the mast positions and the fixture schedule — and we will quote the fittings, but the specifications are confirmed per enquiry rather than listed. If you are comparing suppliers on a floodlighting job, the study is the part worth having from us regardless of who ultimately supplies the fittings, because it gives you a result to compare quotes against.

[PLACEHOLDER: the floodlight range itself — wattages, beam angles, IP rating, warranty and whether asymmetric optics are available. This is the single biggest gap on this page and the reason it is thinner than the other seven.]

[PLACEHOLDER: solar floodlights — the solar-flood category exists in the catalogue but is empty. Confirm what can be supplied.]

Common questions

What wattage floodlight do I need for my yard?

Wattage is the wrong starting point, and for floodlighting it is more misleading than usual because two fittings of the same wattage can perform completely differently depending on their optic. Send the area dimensions, the available mounting positions and heights, and what happens in the space; the photometric study gives you a fixture count and an expected uniformity.

Why is my new floodlight bright but the area still dark?

Almost always the optic. A narrow-beam floodlight concentrates its output into a small bright patch, which reads as very bright while leaving the rest of the area dark and destroying your eyes' adaptation so the dark parts look darker still. An asymmetric or wide-beam optic at the right aiming angle puts the same lumens where they are useful.

How much light does a football pitch need?

It depends entirely on the level of play, and the range is wide — EN 12193 sets very different requirements for training, club competition and televised matches, the last of which also demands vertical illuminance toward cameras and flicker control. The first question is therefore what the pitch will host, including what it might host in five years.

Will floodlights annoy my neighbours?

They will if spill is not controlled, and this is one of the commonest complaints about new installations. Spill is a function of the optic and the aiming angle, both of which can be modelled before anything is bought. A study will show how much light crosses the boundary and what aiming or shielding fixes it.

Do you supply solar floodlights?

[PLACEHOLDER: the solar-flood category is declared in the catalogue but empty. Confirm before publishing this answer.] Our published solar range covers street lighting and garden bollards; see solar lighting.

Can you design the scheme even if we buy the fittings elsewhere?

Yes, and for floodlighting that is often the most useful thing we can do. The photometric study gives you a modelled result — uniformity, spill, fixture count and positions — which is what lets you compare quotes on outcome rather than on wattage and price per unit.

Send the area and what happens in it

Dimensions, available mounting positions and heights, and the use — parking, security, training, competition. You will get a photometric study with the uniformity and spill modelled before anything is bought. Or see street lighting if the area is really a road.

SIM-BI SMART LIFE Ltd · KN 48, YUSSA CITY CENTER GF-46, Kigali, Rwanda · info@sim-bi.com · +250 781272103